IEC 60332-3C PDF

Burning Behaviour of Bunched Cables. IEC The European Commission and The European Cable Industry (EUROPACABLE) are finalising. Definitions. IEC refers to various definitions, together with the following during the standard: .. F – B F. Category C, designation F – 3C F. IECC describes a method of type approval testing to define the ability of bunched cables to resist fire propagation. In this test, a cable specimen.

Author: Faezahn Mikakus
Country: Trinidad & Tobago
Language: English (Spanish)
Genre: Software
Published (Last): 2 March 2013
Pages: 444
PDF File Size: 2.27 Mb
ePub File Size: 3.32 Mb
ISBN: 125-9-17906-249-6
Downloads: 72482
Price: Free* [*Free Regsitration Required]
Uploader: Zolokasa

Cable samples on a horizontal tray in a tunnel type of chamber are burned at The resulting chamber atmosphere is quantitatively analysed for a specified set of gases. Conversion of existing IEC apparatus to measure heat release is accomplished by fitting a small instrumented section of ducting into the exhaust system of the rig and using this with associated FTT gas analysis instrumentation and software and a modified test protocol.

Data logger if purchased. The specimen is deemed to have passed this test, of after burning has ceased, the charred or affected position does not reach within 50mm of the lower edge of the top clamp which is equivalent to mm above the point of flame application. This specifies a test for determination of the amount of halogen acid gas, other than the hydrofluoric acidevolve d during combustion of compound based on halogenated polymers and compounds containing halogenated additives taken from cable constructions.

  ANTONIN ARTAUD TARAHUMARAS PDF

There are four primary fire testing standards as follows: Fire resistant cables are designed to maintain circuit integrity of those vital emergency services during the fire. Due to relative low cost, fire retardant cable s are widely used as fire survival cables.

Fire Testing Technology | IEC

6332-3c In this test, a 1 g cable specimen are completely burnt inside a sealed chambers of volume 0. Wide ladder mmwide: The cable specimen is deemed to have met the requirements of the standard if, after burning has ceased, the extent of charred or affected portion does not reach a height exceeding 2. IEC and IEC are used to assess the flame propagation characteristics of a single wire.

The higher the oxygen index, the more retardant the cable is. IEC is used to assess the flame propagation chacteristics of bundled cables.

Burning Behaviour of Bunched Cables

BS BS specifies the performance requirements for cables required to maintain circuit integrity under fire conditions. Gas Analysis Instrumentation These are housed in a 19″ instrument rack containing: To determine if the cable is halogen free, IEC should be used.

Conquered the Summit of London. Plenum rated cables meet the NFPA standard formerly known as UL which provides the most stringent requirement of all the tests. Carbon Dioxide Analyser infrared for use in heat release measurement. All these elements are toxic by its nature. The European Iev Committee categorized the fire performance of the cables into three classes, namely.

The main concern for the cable in its fire survival properties are its flame spread, smoke characterization and and gas toxicity. Real Time Patching System.

  GARMIN SL30 MANUAL PDF

A single survival category W is defined if the cables surpassed the testing requirement. Fire retardant cables are designed for use in fire situations where the spread of flames along a cable route need to be retarded.

Resistance to fire alone — the cables is tested by gas burner flame while passing a current at its rate voltage. The test method is not suitable for the testing of some small wires due to the melting of the conductors during the time of application of the flame. FTT can supply either laser or white light systems for smoke measurement in compliance with the standard.

The CMG cable is suitable for use in. IECC describes a method of type approval testing to define the ability of bunched cables to resist fire propagation. General purpose cables meets UL This test details a method of test for the assessment of the flame propagation characteristics of a single wire or cable. The higher the toxicity index, the more toxic the cable material is.

IEC TS | IEC Webstore

Test for vertical flame spread of vertically-mounted bunched wires or cables – Category D -Installation In one layer front. The minimum light transmission is recorded. In general, the toxicity index of LSZH material is less than 5.