ASTM D4541 – 09E1 PDF

ASTM D Pull Off Test Standard – Free download as PDF File .pdf), Text File .txt) or read online for free. ASTM D and BS EN ISO describe several different test apparatus; The tensile pull-off method for adhesion testing, as outlined in ASTM D and . ASTM A/AM Steel, Sheet and Strip, Heavy-Thickness Coils, Hot- Rolled, Carbon, Commercial, Drawing, Structural, High-Strength Low-Alloy.

Author: Mezizil Daigal
Country: Qatar
Language: English (Spanish)
Genre: Relationship
Published (Last): 27 June 2013
Pages: 459
PDF File Size: 14.59 Mb
ePub File Size: 8.7 Mb
ISBN: 226-9-37703-154-4
Downloads: 44180
Price: Free* [*Free Regsitration Required]
Uploader: Akinodal

Subscription — always available and updated A web subscription provides asstm easy and secure access to standards, and you are guaranteed to always have the latest edition. Link to Active This link will always route to the current Active version of the standard. Protocol 1 test to fracture determines the greatest perpendicular force in tension that a surface area can bear before a plug of material is detached.

The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.

The procedure in this standard was developed for metal substrates, but may be appropriate for other rigid substrates such as plastic and wood. Pull-off strength of coatings from concrete is described in Test Method D This ensures that 009e1 are always up-to-date and saves you both time and money. There are five instrument types, identified as Test Methods B-F. Method A, which appeared in previous versions of this standard, has been eliminated as its f use is for testing on concrete substrates see Test Method D It is the responsibility of the user of this standard to e1 appropriate safety, health and environmental practices and determine the applicability of regulatory limitations prior to use.

There are five instrument types, identified as Test Methods B-F. Depending on the radius of the surface, the results could have greater variability with lower values and averages.

Note 1—The procedure in this standard was developed for metal substrates, but may be appropriate for other rigid substrates such as plastic and wood. This test method is applicable to any portable apparatus meeting the requirements for determining the pull-off strength of a coating in this standard see Annexes.

It is imperative to identify the test method used when reporting results.

  DAZAI - NO LONGER HUMAN PDF

This includes change in glue, load fixture size, substrate coating cure time, pull rate, environmental conditions, if the coating is scored, or using a different device.

A web subscription provides an easy and secure access to standards, and you are guaranteed to always have the latest edition. Standards monitoring is d free service designed for you who wish to be alerted of changes to or new editions of the standards required in your work.

ASTM D4541 – 09E1 PDF

This test method maximizes tensile stress as compared to the shear stress applied by other methods, such as scratch or knife adhesion, and results may not be comparable. Note 2—Method A, which appeared in previous versions of this standard, has been eliminated as its main use is for testing on concrete substrates see Test Method D Webprint Printed and bound.

They are capable of applying a concentric load and counter load to a single surface so that coatings can be tested even though only one side is accessible. The values given in parentheses are for information only. Failure will occur along the weakest plane within the system comprised of the test fixture, adhesive, coating system, and substrate, and will be exposed by the fracture surface.

Results obtained by each test method may give different results. Historical Version s – view previous versions of standard. It is imperative to identify the test method used when reporting results. Measurements are limited by the strength of adhesive bonds between the loading fixture and the specimen surface or the cohesive strengths of the glue, coating layers, and substrate. They are capable of applying a concentric load and counter load to a single surface so that coatings can be tested even though only one side is accessible.

Pull-off strength of coatings from concrete is described in Test Method D Failure will occur along the weakest plane within the system comprised of the test fixture, adhesive, coating system, and substrate, and will be exposed by the fracture surface. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

This test method maximizes tensile stress as compared to the shear stress applied by other methods, such as scratch or knife adhesion, and results may not be comparable.

  DRUMAGOG 4 MANUAL PDF

ASTM D – 09E1 PDF

Note 2—Method A, which appeared in previous versions of this standard, has been eliminated as its main use is for testing on concrete substrates see Test Method D Depending on the radius of the sstm, the results could have greater variability c4541 lower values and averages.

Therefore, when a series of results will be compared with one another or used for statistical analysis, the type of apparatus, substrate, test procedures, glue type, and if scoring is used should be the same for the pulls considered.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

It is imperative to identify the test method used when reporting results. Method A, which appeared in previous versions of this standard, has been eliminated as its main use is for testing on concrete substrates see Test Method D Pull-off strength of coatings from concrete is described in Test Method D Link to Active This link will always route to the current Active version of the standard. Measurements are limited by the strength of adhesive bonds between the loading fixture and the specimen surface or the cohesive strengths of the glue, coating layers, and substrate.

The procedure in this standard was developed for use on flat surfaces. Link to Active This link will always route to the current Active version of the standard. Note 1—The procedure in this standard was developed for metal substrates, but may be appropriate for other rigid substrates such as plastic and wood.

Link to Active This link will always route to the current Active version of the standard. This test method maximizes tensile stress as compared to the shear stress applied by other methods, such as scratch or knife adhesion, and results may not be comparable. Results should only be assessed for each test method and not be compared with other instruments. Fracture will occur along the weakest plane within the system comprised of the test fixture, glue, coating system, and substrate, and will be exposed by the fracture surface.